Description
|
Specification
|
Physical
|
• Occupies a single slot in the Cisco uBR10012 chassis
• Interface: line card single mode with intermediate reach connector
• Hot-swappable; no slot dependency
• Weight: 16 lb (7.26 kg)
• Dimensions (H x W x D): 20 x 1.36 x 16 in. (50.80 x 3.55 x 10.64 cm)
|
Power
|
• Unit power: 230W at 40°C
|
Reliability and availability
|
• Designed for five 9s of availability
|
Environmental
|
• Operating altitude: -197 to 13,123 ft (-60 to 4000m)
• Storage temperature: –4 to 149°F (-20 to 65°C)
• Operating temperature, nominal: 41 to 104°F (5 to 40°C)
• Storage relative humidity: 5 to 95%
• Operating relative humidity: 10 to 90%
|
Software release
|
• Cisco IOS ® Software Release 12.2(33)SCC or later
|
Regulatory Compliance
|
Safety
|
• CAN/CSA-C22.2 No. 60950-1 1st ed. / UL 60950-1 1st ed. (Safety of Information Technology Equipment)
• EN/IEC 60950-1 (Safety of Information Technology Equipment)
• AS/NZS 60950.1 (Safety of Information Technology Equipment)
|
Electromagnetic Emissions
|
• EN55022, Class B
• CISPR 22, Class B
• FCC 47CFR15, Class B
• ICES-003, Class B
• VCCI, Class B
• AS/NZS CISPR 22, Class B
• KN 22, Class B
• IEC/EN61000-3-2 Power Line Harmonics
• IEC/EN61000-3-3 Voltage Fluctuations and Flicker
|
Electromagnetic Immunity
|
• IEC/EN61000-4-2 Electrostatic Discharge Immunity
• IEC/EN61000-4-3 Radiated Immunity
• IEC/EN61000-4-4 Electrical Fast Transient Immunity
• IEC/EN61000-4-5 Surge
• IEC/EN61000-4-6 Immunity to Conducted Disturbances
• IEC/EN61000-4-11 Voltage Dips, Short Interruptions, and Voltage Variations
|
ETSI/EN
|
• EN 300 386 Telecommunications Network Equipment (EMC)
• EN55022 Information Technology Equipment (Emissions)
• EN55024 Information Technology Equipment (Immunity)
• EN61000-6-1 Generic Immunity Standard
|
Network Equipment Building Systems (NEBS): Level 3
|
Designed to meet requirements of:
• GR-63-CORE, Issue 3, March 2006
• GR-1089-CORE, Issue 4, June 2006
|
Mechanical
|
• Weight: 16 lb (7.26 kg)
Dimensions (H x W x D): 20 x 1.36 x 16 in.
(50.80 x 3.55 x 40.64 cm)
• Operating altitude: -197 to 13,123 ft (-60 to 4000m)
• Storage temperature: -4 to 149°F (-20 to 65°C)
• Operating temperature, nominal: 41 to 104°F (5 to 40°C)
• Storage relative humidity: 5 to 95%
• Operating relative humidity: 10 to 90%
• IEC 68-2-1, IEC 68-2-2, IEC 68-2-56: Operational temperature and humidity
• IEC 68-2-27: Operating shock
• IEC 68-2-64, IEC 68-2-6, IEC 68-2-47: Operating and non-operating vibration
• IEC 68-2-32: Non-operating freefall drop
• IEC 68-2-40: Non-operating altitude
• IEC 68-2-27, IEC 68-2-32: Non-operating mechanical shock
• IEC 68-2-3: Non-operating humidity
• IEC 68-2-14, IEC 68-2-33: Non-operating temperature shock
|
LED
|
• One power LED (green)
• One status LED (green/yellow): solid green indicates the processor has booted and passed its diagnostics; LED blinks green on a protect card, yellow when in one of the booting states
• Maintenance (yellow): indicates the line card can be removed
• One upstream-enabled LED on each upstream port (green): upstream path is configured and able to pass traffic
• One downstream-enabled LED on each downstream port (green): downstream path is configured and able to pass traffic through the upconverter at RF
• LIC1-LIC4 (green) indicate DS licenses installed
• No LED illuminated indicates: 0DS License
• LIC1 illuminated indicates: 5DS License
• LIC1-LIC4 illuminated indicate: 20DS License
• LIC1-LIC4 blinking indicate: No valid license installed. Card will become operational only when a valid license is installed.
|
Network Management Information
|
Standard MIBs
|
• IF-MIB (RFC-2233)
• IP-FORWARD-MIB (RFC-4292)
• ENTITY-MIB (RFC-2737)
• MIBII (RFC1213)
• EtherLike-MIB (RFC-2665)
• IGMP-MIB (RFC-2993)
• RMON-MIB (RFC-1757)
• IP-MIB
• ENTITY-SENSOR-MIB
|
Expression MIBs
|
• SNMPv2-SMI
• SNMPv2-TC
• SNMPv2-MIB
• IANAifType-MIB
|
Simple Network Management Protocol Version 3 (SNMPv3) MIBs
|
• SNMP-FRAMEWORK-MIB (RFC-2571)
• SNMP-MPD-MIB (RFC-2572)
• SNMP-NOTIFICATION-MIB (RFC-2573)
• SNMP-TARGET-MIB (RFC-2573)
• SNMP-USM-MIB (RFC-2574)
• SNMP-VACM-MIB (RFC-2575)
|
DOCSIS and EuroDOCSIS MIB
|
• DOCS-IF-MIB (RFC 4546)
• DOCS-CABLE-DEVICE-MIB (RFC-2669)
• DOCS-BPI-PLUS-MIB (Rev 5)
• DOCS-QOS-MIB (Rev 4)
• DOCS-CABLE-DEVICE-TRAP-MIB
• DOCS-SUBMGT-MIB (Rev 2)
• DOCS-IF3-MIB
• DOCS-QOS3-MIB
• DOCS-DRF-MIB
• DOCS-LOADBAL3-MIB
• DOCS-DIAG-MIB
• DOCS-SUBMGT3-MIB
• CLAB-TOPO-MIB
• DOCS-MCAST-AUTH-MIB
• DOCS-MCAST-MIB
• DOCS-SEC-MIB
• DOCS-IETF-BPI2-MIB
• DOCS-IETF-QOS-MIB
|
Cisco DOCSIS MIBs
|
• CISCO-DOCS-EXT-MIB
• CISCO-DOCS-REMOTE-QUERY-MIB
• CISCO-DOCS-QOS-EXT-MIB
• CISCO-CABLE-SPECTRUM-MIB
• CISCO-CABLE-AVAILABILITY-MIB
• CISCO-DOCS-EXT-CAPABILITY-MIB
• CISCO-CABLE-WIDEBAND-MIB
|
Cisco Generic MIBs
|
• CISCO-SYSLOG-MIB
• CISCO-SMI-MIB
• CISCO-TC-MIB
• CISCO-PRODUCTS-MIB
• CISCO-FLASH-MIB
• CISCO-CONFIG-MAN-MIB
• CISCO-CONFIG-COPY-MIB
• CISCO-MEMORY-POOL-MIB
• CISCO-BULK-FILE-MIB
• CISCO-SONET-MIB
• CISCO-TCP-MIB
• CISCO-RTTMON-MIB
• CISCO-FTP-CLENT-MIB
• CISCO-IPMROUTE-MIB
• CISCO-QUEUE-MIB
• CISCO-IMAGE-MIB
• CISCO-ENVMON-MIB
• CISCO-ENTITY-VENDORTYPE-OID-MIB
• CISCO-PRODUCTS-MIB
|