Description
Cisco N3K-C3064PQ-10GX, Nexus 3064-X, 48 SFP+, 4 QSFP+ ports, with enh scale, low- l (Both airflows, dual AC, 1x FAN).
N3K-C3064PQ-10GX is the Nexus 3064-X, 48 SFP+ and 4 QSFP+ ports, with enhanced scale, low latency. The Cisco Nexus 3064-X, 3064-T, and 3064-32T Switches are high-performance, high-density Ethernet switches that are part of the Cisco Nexus 3000 Series Switches portfolio. These compact one-rack-unit (1RU) form-factor 10 Gigabit Ethernet switches provide line-rate Layer 2 and 3 switching. They run the industry-leading Cisco® NX‑OS Software operating system, providing customers with comprehensive features and functions that are widely deployed globally. They support both forward and reverse airflow schemes with AC and DC power inputs. The Cisco Nexus 3064 switches are well suited for data centers that require cost-effective, power-efficient, line-rate Layer 2 and 3 top-of-rack (ToR) switches.
Linkom-PC is your source for Refurbished Cisco N3K-C3064PQ-10GX. Most Cisco N3K-C3064PQ-10GX are available within 3-4 days.
We make sure each item you receive is ready to use. Any configuration is reset to factory default settings in our REF process.
If you cannot find the product you are searching for, please request a quote.
WHY LINKOM-PC?
- Save 90%+ off the list
- Professional Advice
- Fully Tested
- Fast Delivery
Cisco N3K-C3064PQ-10GX Technical Specifications
N3K-C3064PQ-10GX Specification | ||
Physical | ● 1RU fixed form factor ● Cisco Nexus 3064-X: 64 10 Gigabit Ethernet ports (48 SFP+ and 4 QSFP+) ◦ 48 SFP ports support 1 and 10 Gigabit Ethernet ◦ 4 QSFP ports support 4 x 10 Gigabit Ethernet or 40 Gigabit Ethernet each ● 2 redundant power supplies ● 1fan tray with redundant fans ● 1 I/O module with management, console, and USB flash memory ports | |
Performance | ● 1.28-Tbps switching capacity ● Forwarding rate of 950 mpps ● Line-rate traffic throughput (both Layer 2 and 3) on all ports ● Configurable maximum transmission units (MTUs) of up to 9216 bytes (jumbo frames) | |
Hardware tables and scalability | MAC addresses | 128,000 |
Number of VLANS | 4096 | |
Spanning-tree instances | ● Rapid Spanning Tree Protocol (RSTP): 512 ● Multiple Spanning Tree (MST) Protocol: 64 | |
ACL entries | ● 2000 ingress ● 1000 egress | |
Routing table | ● 16,000 prefixes and 16,000 host entries ● 8000 multicast routes | |
Number of EtherChannels | 64 (with vPC) | |
Number of ports per EtherChannel | 32 | |
Buffers | 9 MB shared | |
Boot flash memory | 2 GB | |
Power | Number of power supplies | 2 ● Cisco Nexus 3064-X: Redundant for AC and DC power |
Power supply types | ● AC (forward and reversed airflow) ● DC (forward and reversed airflow) | |
Typical operating power | ● Cisco Nexus 3064-X ◦ 143 watts (W; 64p with Twinax at 100% load; 2 power supply units [PSUs]) ◦ 177W (64p with SR optics at 100% load; 2 PSUs) | |
Maximum power | ● Cisco Nexus 3064-X: 199W | |
AC PSUs ● Input voltage ● Frequency ● Efficiency | ● 100 to 240 VAC ● 50 to 60 Hz ● 89 to 91% at 220V | |
DC PSUs ● Input voltage ● Maximum current ● Efficiency | ● -40 to -72 VDC ● 33A ● 85 to 88% | |
Typical heat dissipation | ● Cisco Nexus 3064-X ◦ 488 BTU/hr (64p with Twinax at 100% load; 2 PSUs) ◦ 605 BTU/hr (64p with SR optics at 100% load; 2 PSUs) | |
Maximum heat dissipation | ● Cisco Nexus 3064-X: 683 BTU/hr | |
Cooling | Forward and reversed airflow schemes: ● Forward airflow: Port-side exhaust (air enters through fan-tray and power supplies and exits through ports) ● Reversed airflow: Port-side intake (air enters through ports and exits through fan-tray and power supplies) Single fan tray with redundant fans Hot swappable (must swap within 1 min) | |
Sound | Measured sound power (maximum) ● Fan speed: 40% duty cycle ● Fan speed: 60% duty cycle ● Fan speed: 100% duty cycle | ● 59.7 dBA ● 66.4 dBA ● 71.0 dBA |
Environment | Dimensions (height x width x depth) | ● Cisco Nexus 3064-X: 1.72 x 17.3 x 19.7 in. (4.4 x 43.9 x 50.5 cm) |
Weight | ● Cisco Nexus 3064-X: 20.5 lb (9.3 kg) | |
Operating temperature | 32 to 104°F (0 to 40°C) | |
Storage temperature | -40 to 158°F (-40 to 70°C) | |
Operating relative humidity | ● 10 to 85% noncondensing ● Up to 5 days at maximum (85%) humidity ● Recommend ASHRAE data center environment | |
Storage relative humidity | 5 to 95% noncondensing | |
Altitude | 0 to 10,000 ft (0 to 3000m) |