Description
Cisco 76-ES+XC-20G3C, 7600 ES+XC Combo 10x1GE/ 1x10GE, DFC3C.
7600 Series Ethernet Services Plus Extended Combination (ES Plus XC) line cards are designed for interface-flexible Ethernet services. They allow service prioritization for voice, video, data, and wireless mobility services and can connect to LAN, WAN, and Optical Transport Network Physical Layer (OTN PHY) interfaces as well as Gigabit Ethernet ports on the same physical line card. This unique form factor allows for configurations with redundant network-to-network 10 Gigabit Ethernet interfaces to reside on separate line card slots for resiliency, while offering user-to-network Gigabit Ethernet interfaces on the same slots for efficiency. Service providers and enterprises benefit from the efficiency gains in power consumption, optimized service scale, and feature capability as well as the flexibility in interface speeds for Ethernet solutions.
The ES Plus XC cards use the ES Plus card family architecture that relies on programmable interface processors, protecting network investments and reducing total cost of ownership. The extensible design maximizes connectivity options and offers superior service intelligence through programmable interface processors operating at line rate.
Key Features and Benefits of the Cisco 7600 Series ES Plus XC line card
Feature | ES Plus line cards | Benefit |
Line card form factor | 2x10GE and 20xGE
1x10GE and 10xGE | Offers economical, high-density, high-performance, premium Carrier Ethernet services with excellent scalability for solutions that require uplink redundancy with slot diversity
LAN PHY support at FCS. WAN and OTN PHY support in a post FCS software release. |
Performance | Line rate with services enabled | Provides line-rate forwarding performance on GE and 10 GE interfaces with services enabled |
Packet memory | 512 MB | Up to 200 ms combined bidirectional buffering |
Switch fabric connectivity | Two 20-Gbps fabric channels | Utilizes the Cisco 7600 Series 720-Gbps switch fabric for data forwarding; 2 fabric channels are utilized that are not present in slots 1 through 8 on the Cisco 7613 chassis |
Online insertion and removal (OIR) | Supports OIR of the line cards | Provides hitless OIR to minimize impact of add/change/remove operations |
Product Specifications
Description | Specification |
Chassis compatibility | All Cisco 7600 Series Router chassis, except the Cisco 7603, which has reached end of sale/end of life. The Cisco 7603-S is fully supported. |
Central forwarding engine compatibility | Cisco Supervisor Engine 720-3B, 720-3BXL, Route Switch Processor 720 (RSP720) 3C/3CXL and RSP720-10GE 3C/3CXL.
The ES Plus line cards require dual-channel switch fabric connectivity; therefore, they are not supported with the Supervisor Engine 32 or in slots 1 through 8 of the Cisco 7613 chassis. |
Distributed forwarding card (DFC) | Choice of Cisco Distributed Forwarding Card 3C (DFC-3C) or DFC-3CXL
Line-rate distributed forwarding with services enabled, up to ~48 Mpps per line card
DFC-3C
Designed for Carrier Ethernet-based infrastructures
Up to 256,000 hardware-based forwarding entries with DFC-3C
Up to 128,000 NetFlow entries with DFC-3C
DFC-3CXL
Optimized for IP/MPLS provider edge offering multiple IP services such as Layer 3 VPNs, IPv6, and triple- or quad-play services
Up to 1 million hardware-based forwarding entries with DFC-3CXL
Up to 256,000 NetFlow entries with DFC-3CXL |
Minimum software | Cisco IOS® Software Release 12.2SRE or later |
Packet memory | 512 MB for 200 ms of combined input and output buffering at 10 Gbps |
Link encapsulations | Ethernet II and IEEE 802.1q encapsulations |
Hardware queues | ES Plus XC 40G and 20G line cards
128,000 queues per line card
Hierarchical QoS (H-QoS) |
MAC addresses | Up to 96,000 MAC addresses per ES Plus XC line card
16,000 VLAN IDs per line card (within Flexible QinQ configuration guidelines)
Hardware-based MAC learning at wire rate |
Environmental conditions | Operating temperature: 32 to 104°F (0 to 40°C)
Storage temperature: -40 to 167°F (-40 to 75°C)
Relative humidity: 10 to 90 percent, non-condensing
Operating altitude: -60 to 2000m |
MIBs | Cisco Optical Transport Network MIB (CISCO-OTN-MIB)
Cisco Entity MIB (CISCO-ENTITY-MIB)
Cisco Entity Asset MIB
Cisco Entity Field-Replaceable Unit (FRU) Control MIB
Cisco Entity Alarm MIB
Interface IF MIB (RFC 2233)
Definitions of Managed Objects for Bridges (RFC 1493)
Evolution of Interfaces Group of MIB-II (RFC 1573)
SNMP MIB II (RFC 1213)
Remote Monitoring (RMON) MIB (RFC 1757)
Switch Monitoring (SMON) MIB
Video Monitoring MIBs:
CISCO-FLOW-MONITOR-TC-MIB, CISCO-FLOW-MONITOR-MIB
CISCO-MDI-METRICS-MIB, CISCO-IP-CBR-METRICS-MIB
Details on the MIBs above can be found at this link: http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/7600mibs/ |
Network management | CiscoWorks, CiscoView, and CiscoWorks Resource Manager Essentials (RME), Cisco ANA, Cisco VAMS. |
Physical specifications | Occupies one slot in a Cisco 7600 Series Router
Up to 8 ES Plus line cards (any type) in a Cisco 7609 or 7609-S 9-slot chassis
Requires Cisco Supervisor Engine 720-3B or 3BXL, RSP720 or later
Dimensions (H x W x D): 1.75 x 15.375 x 16 in.
Weight:
• 76-ES+XC-20G3C/XL: 11.8 lb
• 76-ES+XC-40G3C/XL: 12.5 lb |
Maximum power consumption (watts) | 76-ES+XC-20G3C 309.3W
76-ES+XC-20G3CXL 316.8W
76-ES+XC-40G3C 392.3W
76-ES+XC-40G3CXL 427.2W |
Indicators | Status: green (operational); orange (faulty) |
Regulatory compliance | CE Marking |
Safety | UL 60950
CSA C22.2 No. 60950
EN60950
TS001
IEC 60950
AS/NZS3260
ITU-T G.664 (Automatic Laser Shutdown – ALS) |
Electromagnetic compatibility | FCC Part 15 Class A
ICES-003 Class A
VCCI Class A
EN55022 Class A
CISPR22 Class A
AS/NZS3548 Class A
EN61000-3-2
EN61000-3-3
EN55024
EN61000-6-1
EN50082-1
EN300 386 |
Telecommunications standards | ITU-T G.664 (ALS)
ITU-T G.691
ITU-T G.707
ITU-T G.709 (OTN)
ITU-T G.783 Sections 9-10
ITU-T G.784
ITU-T G.803
ITU-T G.813
ITU-T G.825
ITU-T G.826
ITU-T G.841
ITU-T G.957 Table 3
ITU-T G.958FCC Part 15 Class A
ITU-T G.975.I.4 (EFEC) |
Network clock references | GR-253-CORE (SONET)
GR-1244-CORE (BITS)
G.8261 (No SSM)
G.8262
G.8264 (No ESMC) |
Feature Support
Description | Specification |
Carrier Ethernet and IP/MPLS network protocols | IPv4 Unicast and Multicast
IPv6 Unicast and Multicast
Layer 2 multicast
MPLS Provider Edge Layer 2 and Layer 3 VPNs
MPLS Traffic Engineering (MPLS-TE)
MPLS Fast Reroute (FRR)
Differentiated Services (Diff-Serv) aware MPLS TE
Generic Routing Encapsulation (GRE) and IP-in-IP Tunneling
Ethernet Bridging and Ethernet Multipoint Bridging (E-MPB)
Ethernet Switching
Ethernet over MPLS (EoMPLS)
Switch port – access and trunk
QinQ Termination
Selective QinQ
Flexible QinQ
VLAN Translation
Private VLAN
VPLS and H-VPLS
VLAN and Spanning Tree Protocols
Per VLAN Spanning Tree (PVST)
Virtual Switch Tagging (VST)
Rapid Spanning Tree Protocol (RSTP)
Multiple Spanning Tree (MST) Protocol – IEEE 802.1s
VLAN ACL (VACL)
VLAN Trunking Protocol (VTP)
Ethernet Operations, Administration, and Maintenance (E-OAM), Connection
Fault Management (CFM), and Y.1731
802.1ah |
QoS | Modular QoS CLI (MQC)
Policing granularity down to ingress, egress, physical interfaces, and VLAN
Access control lists
Classification, marking, policing, and queuing
Diff-Serv Code Point (DSCP)
Complex re-marking of Ethernet and IP/MPLS headers |
Congestion avoidance | Weighted Random Early Detection (WRED) based on IP Prec, DSCP, MPLS EXP |
Queuing and shaping | Enhanced Class-Based Weighted Fair Queuing (CBWFQ)
Egress low-latency queuing (LLQ); traffic inside LLQ may be shaped
Two levels of queuing hierarchy
Egress shaping |
Traffic classification and bandwidth policing | Classification based on:
Extended ACL
IP Precedence/IP DSCP
MPLS Experimental Bits (EXP)
VLAN
Input VLAN
Policer: Ingress single- and dual-rate, three color |
ACLs and security | Up to 32,000 access list entries with no forwarding degradation
Hardware counters for ACL hits |
Layer 2 and Layer 3 VPNs | Layer 2 VPNs
EoMPLS with MAC learning
H-VPLS (MPLS edge or IEEE 802.1ad edge)
Flexible QinQ
Layer 3 VPNs
MPLS VPN (RFC 2547-bis)
Inter-AS and Carrier-Supporting-Carrier
Multicast VPN (mVPN)
mLDP based Multicast VPN (mVPN)
Multicast VPN Extranet
802.1ah |
Protection and bundling | MPLS Fast Reroute
IEEE 802.3ad and EtherChannel® |
Inline Video Monitoring Feature Support
Description | Specification |
Summary | Supported on all ES+ linecards
Supported with supervisor engines Sup720 and RSP720 (1 gigabits and 10 gigabits)
Monitoring on both ingress and egress interfaces
IP/UDP encapsulated unicast and multicast video streams
VBR and CBR video streams
Compressed and uncompressed video streams |
Metrics | RFC4445 Media Delivery Index (MDI) consisting of Delay Factor (DF), and Media Loss Rate (MLR), plus Media Discontinuity Count (MDC) – for MPEG video within M2TS (SPTS/MPTS)
Delay Factor and Media Rate Variation (MRV)
MDI:DF, MDI:MLR, MDI:MDC, IP-CBR:DF, and IP-CBR:MRV metrics are supported for CBR flows
MDI:MLR and MDI:MDC are supported for VBR flows |
Performance | Flow rates up to 10Gbps and a total of up to 40Gbps per linecard
Up to 8000 flows per chassis and 1000 flows per linecard |
Management | Media Stop Events (MSE)
Threshold Crossing Alerts (TCA)
Syslog support
SNMP MIBs
Full integration with Cisco’s Video Assurance Management Solution (VAMS)
http://www.cisco.com/en/US/products/ps9518/index.html |
OTN Feature Support (10 Gigabit Ethernet ports only)
Description | Specification |
Protocol support | OTN G.709 compliant, selectable
Mapping of IEEE 802.3ae 10GBASE-R signal into an overclocked
OPU1e running at 11.0491 Gbps
OPU2e running at 11.0975 Gbps
Internal (system) and line (network) loopback
Local (internal) or loop (recovered from network) timing
±100 ppm local clock accuracy over operating temperature |
Alarms and performance monitoring | Alarm reporting:
• Loss of signal (LOS)
• Loss of OTN frame (LOF)
• Loss of OTN multiframe (LOM)
• OTU alarm indication signal (OTU-AIS)
• OTU backward defect indication (OTU-BDI)
• ODU alarm indication signal (ODU-AIS)
• ODU open connection indication (ODU-OCI)
• ODU locked (ODU-LCK)
• ODU backward defect indication (ODU-BDI)
• ODU payload type identifier mismatch (ODU-PTIM)
• OTU incoming alignment (OTU-IAE)
OTU_SF_BER and OTU_SD_BER alarms are based on monitoring OTU BIP errors with a user-settable threshold crossing.
Error counts: OTU BIP, OTU BEI, ODU BIP, and ODU BEI.
Threshold crossing alerts (TCAs) for OTU BIP errors (SM-TCA) and ODU BIP errors (PM-TCA) with user-settable threshold. |
FEC features | No FEC: ability to turn off error correction for use with non-FEC supporting interfaces.
GFEC: standard G.709
EFEC: standard G.975.I.4
FEC statistics for corrected errors (EC), last second corrected errors (EC), and uncorrected words (UC). |
DWDM Line Interface Specification (10 Gigabit Ethernet ports only)
Description | Specification |
Bit rate | 9.953280 Gbps +/- 4.6 ppm
10.3125 Gbps +/- 4.6 ppm
11.049 Gbps +/- 4.6 ppm
11.0957 Gbps +/- 4.6 ppm |
Spectral width at 20dB (lambda delta20) | ≤ 30 GHz |
Optical Transmitter |
Type | Lithium niobate external modulator |
Output power (PTmin to PTmax) | -1 dBm, + 3 dBm |
Required optical return loss, minimum (ORLmin) | 27 dB |
Extinction ratio, minimum (reminx) | > 9 dB |
Laser safety class | 1 |
Optical Receiver |
Type | Avalanche photo diode (APD) |
Chromatic dispersion tolerance (DLRmax) | Up to 1600 ps/nm |
Minimum BER (BERmin)
FEC off
FEC on
E-FEC on |
10E-12
10E-15
10E-15 |
Reflectance between far-end Tx and near-end Rx (maximum) | -27 dB |
Input wavelength bandwidth (lambdac_rx) | 1260 nm to 1607 nm |
Connector type (Tx/Rx) | LC, duplex |
Optical Performance (10 Gigabit Ethernet ports only)
DWDM XFP Fixed Wavelength |
Long wavelength performance (1529 nm to 1562 nm C-band) |
No FEC applications (Note b) applicable at 9.9 Gbps, 10.3 Gbps only |
Pin @ 23dB OSNR, BER<10-12 | | -7 to -23 | dBm |
Pin @ 23dB OSNR, BER<10-12 | -500 to +1600 ps/nm | -7 to -20 | dBm |
No FEC applications applicable at 9.9 Gbps, 10.3 Gbps only |
Pin @ 17dB OSNR, BER<10-12 | | -7 to -18 | dBm |
Pin @ 20dB OSNR, BER<10-12 | -500 to +1600 ps/nm | -7 to -18 | dBm |
FEC applications (Note c) applicable at 11.09 Gbps only |
Pin @ 11 dB OSNR, BER<10-5 | | -7 to -18 | dBm |
Pin @ 12 dB OSNR, BER<10-5 | -500 to +1100 ps/nm | -7 to -18 | dBm |
Enhanced-FEC applications (Note c) applicable at 11.09 Gbps only |
Pin @ 23dB OSNR, BER<7*10-4 | | -7 to -27 | dBm |
Pin @ 23dB OSNR, BER<7*10-4 | -500 to +1300 ps/nm | -7 to -24 | dBm |
Enhanced-FEC applications (Note c) applicable at 11.09 Gbps only |
Pin @ 8 dB OSNR, BER<7*10-4 | | -7 to -18 | dBm |
Pin @ 9dB OSNR, BER<7*10-4 | -500 to +1100 ps/nm | -7 to -18 | dBm |
SONET/SDH WAN PHY Feature Support (10 Gigabit Ethernet ports only)
SONET/SDH Features and Functions | Ethernet WAN Interface | Comments |
Synchronization | Supported | Ethernet WAN interface cannot be used in SONET/SDH rings |
Section, Line, and Path BIP8 | Supported | Errors are detected and counted |
Section Trace | Supported | |
Pointer operation/action | Supported | H1, H2 are used to get the location of SPE |
Defects or anomalies – LOS, SEF, LOF, S-BIP, L-BIP, AIS-L, RDI-L, AIS-P, LOP-P, P-BIP, PLM-P | Supported | Counters for section, line, and path BIP errors |
ES Plus Cards Line Card XFP and SFP Modules Supported
Part Number for ES Plus line cards 10-Gbps Small Form-Factor Pluggable (XFP) | Wavelength | Mode | Distance |
XFP-10GZR-OC192LR, LAN-PHY | 1550 nm | Single mode (SM) | 49.7 miles (80 km) |
XFP-10GER-OC192IR+, LAN-PHY | 1550 nm | SM | 24.8 miles (40 km) |
XFP-10GLR-OC192SR, LAN-PHY | 1310 nm | SM | 6.2 miles (10 km) |
SFP-GE-S | 850 nm | Multimode (MM) | 1804 ft (550m) |
SFP-GE-L | 1310 nm | SM | 6.2 miles (10 km) |
SFP-GE-Z | 1550 nm | SM | 43.5 miles (70 km) |
SFP-GE-T | – | – | 328 ft (100m) |
Ordering Information for Cisco ES Plus line cards GE Gigabit Interface Converter (GLC) Modules
Product Number | Description |
GLC-BX-D | 1000BASE-BX10 SFP module for single-strand SMF, 1490-nm TX/1310-nm RX wavelength |
GLC-BX-U | 1000BASE-BX10 SFP module for single-strand SMF, 1310-nm TX/1490-nm RX wavelength |
Ordering Information for Cisco ES Plus line cards 10 GE Dense Wavelength Division Multiplexing (DWDM) XFP Modules
Note: The following DWDM XFP products are orderable as spares only.
Product Number | Description | ITU Channel |
DWDM-XFP-60.61= | 10GBASE-DWDM 1560.61 nm XFP (100-GHz ITU grid) | 21 |
DWDM-XFP-59.79= | 10GBASE-DWDM 1559.79 nm XFP (100-GHz ITU grid) | 22 |
DWDM-XFP-58.98= | 10GBASE-DWDM 1558.98 nm XFP (100-GHz ITU grid) | 23 |
DWDM-XFP-58.17= | 10GBASE-DWDM 1558.17 nm XFP (100-GHz ITU grid) | 24 |
DWDM-XFP-56.55= | 10GBASE-DWDM 1556.55 nm XFP (100-GHz ITU grid) | 26 |
DWDM-XFP-55.75= | 10GBASE-DWDM 1555.75 nm XFP (100-GHz ITU grid) | 27 |
DWDM-XFP-54.94= | 10GBASE-DWDM 1554.94 nm XFP (100-GHz ITU grid) | 28 |
DWDM-XFP-54.13= | 10GBASE-DWDM 1554.13 nm XFP (100-GHz ITU grid) | 29 |
DWDM-XFP-52.52= | 10GBASE-DWDM 1552.52 nm XFP (100-GHz ITU grid) | 31 |
DWDM-XFP-51.72= | 10GBASE-DWDM 1551.72 nm XFP (100-GHz ITU grid) | 32 |
DWDM-XFP-50.92= | 10GBASE-DWDM 1550.92 nm XFP (100-GHz ITU grid) | 33 |
DWDM-XFP-50.12= | 10GBASE-DWDM 1550.12 nm XFP (100-GHz ITU grid) | 34 |
DWDM-XFP-48.51= | 10GBASE-DWDM 1548.51 nm XFP (100-GHz ITU grid) | 36 |
DWDM-XFP-47.72= | 10GBASE-DWDM 1547.72 nm XFP (100-GHz ITU grid) | 37 |
DWDM-XFP-46.92= | 10GBASE-DWDM 1546.92 nm XFP (100-GHz ITU grid) | 38 |
DWDM-XFP-46.12= | 10GBASE-DWDM 1546.12 nm XFP (100-GHz ITU grid) | 39 |
DWDM-XFP-44.53= | 10GBASE-DWDM 1544.53 nm XFP (100-GHz ITU grid) | 41 |
DWDM-XFP-43.73= | 10GBASE-DWDM 1543.73 nm XFP (100-GHz ITU grid) | 42 |
DWDM-XFP-42.94= | 10GBASE-DWDM 1542.94 nm XFP (100-GHz ITU grid) | 43 |
DWDM-XFP-42.14= | 10GBASE-DWDM 1542.14 nm XFP (100-GHz ITU grid) | 44 |
DWDM-XFP-40.56= | 10GBASE-DWDM 1540.56 nm XFP (100-GHz ITU grid) | 46 |
DWDM-XFP-39.77= | 10GBASE-DWDM 1539.77 nm XFP (100-GHz ITU grid) | 47 |
DWDM-XFP-38.98= | 10GBASE-DWDM 1538.98 nm XFP (100-GHz ITU grid) | 48 |
DWDM-XFP-38.19= | 10GBASE-DWDM 1538.19 nm XFP (100-GHz ITU grid) | 49 |
DWDM-XFP-36.61= | 10GBASE-DWDM 1536.61 nm XFP (100-GHz ITU grid) | 51 |
DWDM-XFP-35.82= | 10GBASE-DWDM 1535.82 nm XFP (100-GHz ITU grid) | 52 |
DWDM-XFP-35.04= | 10GBASE-DWDM 1535.04 nm XFP (100-GHz ITU grid) | 53 |
DWDM-XFP-34.25= | 10GBASE-DWDM 1534.25 nm XFP (100-GHz ITU grid) | 54 |
DWDM-XFP-32.68= | 10GBASE-DWDM 1532.68 nm XFP (100-GHz ITU grid) | 56 |
DWDM-XFP-31.90= | 10GBASE-DWDM 1531.90 nm XFP (100-GHz ITU grid) | 57 |
DWDM-XFP-31.12= | 10GBASE-DWDM 1531.12 nm XFP (100-GHz ITU grid) | 58 |
DWDM-XFP-30.33= | 10GBASE-DWDM 1530.33 nm XFP (100-GHz ITU grid) | 59 |
Cisco ES Plus line cards GE DWDM SFP Modules
Note: The following DWDM SFP products are orderable as spares only.
Product Number | Description | ITU Channel |
DWDM-SFP-6141= | 1000BASE-DWDM 1561.42 nm SFP (100-GHz ITU grid) | 20 |
DWDM-SFP-6061= | 1000BASE-DWDM 1560.61 nm SFP (100-GHz ITU grid) | 21 |
DWDM-SFP-5979= | 1000BASE-DWDM 1559.79 nm SFP (100-GHz ITU grid) | 22 |
DWDM-SFP-5898= | 1000BASE-DWDM 1558.98 nm SFP (100-GHz ITU grid) | 23 |
DWDM-SFP-5817= | 1000BASE-DWDM 1558.17 nm SFP (100-GHz ITU grid) | 24 |
DWDM-SFP-5736= | 1000BASE-DWDM 1557.36 nm SFP (100-GHz ITU grid) | 25 |
DWDM-SFP-5655= | 1000BASE-DWDM 1556.55 nm SFP (100-GHz ITU grid) | 26 |
DWDM-SFP-5575= | 1000BASE-DWDM 1555.75 nm SFP (100-GHz ITU grid) | 27 |
DWDM-SFP-5494= | 1000BASE-DWDM 1554.94 nm SFP (100-GHz ITU grid) | 28 |
DWDM-SFP-5413= | 1000BASE-DWDM 1554.13 nm SFP (100-GHz ITU grid) | 29 |
DWDM-SFP-5332= | 1000BASE-DWDM 1553.33 nm SFP (100-GHz ITU grid) | 30 |
DWDM-SFP-5252= | 1000BASE-DWDM 1552.52 nm SFP (100-GHz ITU grid) | 31 |
DWDM-SFP-5172= | 1000BASE-DWDM 1551.72 nm SFP (100-GHz ITU grid) | 32 |
DWDM-SFP-5092= | 1000BASE-DWDM 1550.92 nm SFP (100-GHz ITU grid) | 33 |
DWDM-SFP-5012= | 1000BASE-DWDM 1550.12 nm SFP (100-GHz ITU grid) | 34 |
DWDM-SFP-4931= | 1000BASE-DWDM 1549.32 nm SFP (100-GHz ITU grid) | 35 |
DWDM-SFP-4851= | 1000BASE-DWDM 1548.51 nm SFP (100-GHz ITU grid) | 36 |
DWDM-SFP-4772= | 1000BASE-DWDM 1547.72 nm SFP (100-GHz ITU grid) | 37 |
DWDM-SFP-4692= | 1000BASE-DWDM 1546.92 nm SFP (100-GHz ITU grid) | 38 |
DWDM-SFP-4612= | 1000BASE-DWDM 1546.12 nm SFP (100-GHz ITU grid) | 39 |
DWDM-SFP-4532= | 1000BASE-DWDM 1545.32 nm SFP (100-GHz ITU grid) | 40 |
DWDM-SFP-4453= | 1000BASE-DWDM 1544.53 nm SFP (100-GHz ITU grid) | 41 |
DWDM-SFP-4373= | 1000BASE-DWDM 1543.73 nm SFP (100-GHz ITU grid) | 42 |
DWDM-SFP-4294= | 1000BASE-DWDM 1542.94 nm SFP (100-GHz ITU grid) | 43 |
DWDM-SFP-4214= | 1000BASE-DWDM 1542.14 nm SFP (100-GHz ITU grid) | 44 |
DWDM-SFP-4134= | 1000BASE-DWDM 1541.35 nm SFP (100-GHz ITU grid) | 45 |
DWDM-SFP-4056= | 1000BASE-DWDM 1540.56 nm SFP (100-GHz ITU grid) | 46 |
DWDM-SFP-3977= | 1000BASE-DWDM 1539.77 nm SFP (100-GHz ITU grid) | 47 |
DWDM-SFP-3898= | 1000BASE-DWDM 1538.98 nm SFP (100-GHz ITU grid) | 48 |
DWDM-SFP-3819= | 1000BASE-DWDM 1538.19 nm SFP (100-GHz ITU grid) | 49 |
DWDM-SFP-3739= | 1000BASE-DWDM 1537.40 nm SFP (100-GHz ITU grid) | 50 |
DWDM-SFP-3661= | 1000BASE-DWDM 1536.61 nm SFP (100-GHz ITU grid) | 51 |
DWDM-SFP-3582= | 1000BASE-DWDM 1535.82 nm SFP (100-GHz ITU grid) | 52 |
DWDM-SFP-3504= | 1000BASE-DWDM 1535.04 nm SFP (100-GHz ITU grid) | 53 |
DWDM-SFP-3425= | 1000BASE-DWDM 1534.25 nm SFP (100-GHz ITU grid) | 54 |
DWDM-SFP-3346= | 1000BASE-DWDM 1533.47 nm SFP (100-GHz ITU grid) | 55 |
DWDM-SFP-3268= | 1000BASE-DWDM 1532.68 nm SFP (100-GHz ITU grid) | 56 |
DWDM-SFP-3190= | 1000BASE-DWDM 1531.90 nm SFP (100-GHz ITU grid) | 57 |
DWDM-SFP-3112= | 1000BASE-DWDM 1531.12 nm SFP (100-GHz ITU grid) | 58 |
DWDM-SFP-3033= | 1000BASE-DWDM 1530.33 nm SFP (100-GHz ITU grid) | 59 |
Cisco ES Plus line cards GE CWDM SFP Modules
Note: The following CWDM SFP products are orderable as spares only.
Product Number | Description | Color |
CWDM-SFP-1470= | Cisco CWDM 1470-nm SFP; Gigabit Ethernet and 1 and 2 Gb Fiber Channel | Gray |
CWDM-SFP-1490= | Cisco CWDM 1490-nm SFP; Gigabit Ethernet and 1 and 2 Gb Fiber Channel | Violet |
CWDM-SFP-1510= | Cisco CWDM 1510-nm SFP; Gigabit Ethernet and 1 and 2 Gb Fiber Channel | Blue |
CWDM-SFP-1530= | Cisco CWDM 1530-nm SFP; Gigabit Ethernet and 1 and 2-Gb Fiber Channel | Green |
CWDM-SFP-1550= | Cisco CWDM 1550-nm SFP; Gigabit Ethernet and 1 and 2 Gb Fiber Channel | Yellow |
CWDM-SFP-1570= | Cisco CWDM 1570-nm SFP; Gigabit Ethernet and 1 and 2 Gb Fiber Channel | Orange |
CWDM-SFP-1590= | Cisco CWDM 1590-nm SFP; Gigabit Ethernet and 1 and 2 Gb Fiber Channel | Red |
CWDM-SFP-1610= | Cisco CWDM 1610-nm SFP; Gigabit Ethernet and 1 and 2 Gb Fiber Channel | Brown |
Licensing Information
Cisco 7600 Series ES Plus Basic IP License
The ES Plus line cards have two feature license options with the following part numbers: 76-ES+BASIC-LIC (Basic license, including IPv6) and 76-ES+ADVIP-LIC (Advanced IP license).
The Basic license entitles you to use the Cisco IOS Software Release 12.2SR or Release 15S functions on the Cisco 7600 ES Plus line cards with the following exceptions:
• Multicast VPN (MVPN)
• Layer 3 IP/MPLS VPN/6VPE
• Cisco Intelligent Services Gateway (ISG)
• Optical Transport Network (OTN) – IPoDWDM
• Inline Video Monitoring (Vidmon)
Cisco 7600 Series ES Plus Advanced IP License
The Advanced IP license entitles the use of Cisco IOS Software Release 12.2SR or Release 15S on the Cisco 7600 Series ES Plus line cards with the following functions in addition to the Basic license:
• 6VPE
• Layer 3 IP/MPLS VPN
• MVPN
One Advanced IP license is needed for each of the ES Plus line cards in the system where these features are enabled.
The Advanced IP license does not entitle you to use features contained in the Optical Transport Network, Intelligent Services Gateway, or Video Services licenses on the Cisco 7600 Series ES Plus line cards.
Cisco 7600 Series ES Plus Optical Transport Network License
The Optical Transport Network license (part number 76-ES+OTN-LIC) is available for purchase when the OTN capability (G.709/FEC/EFEC) is to be used, and is required on each line card where OTN will be enabled.
Cisco 7600 Series ES Plus Intelligent Services Gateway License
The Intelligent Services Gateway license (part number 76-ES+ISG-LIC) entitles use of the BNG features of Cisco IOS Software Release 12.2SR or Release 15S on the Cisco 7600 Series ES Plus line cards.
• The 76-ES+ISG-LIC is purchased per chassis in increments of 8000 subscribers requiring BNG features with eight MPLS VPNs per license.
Cisco 7600 Series ES Plus Video Monitoring License
The ES Plus Video Monitoring license (part number 76-ES+VIDEO-LIC) is available for purchase when the Video Monitoring capability is to be used, and is required on each chassis where Video Monitoring will be performed
Ordering Information
Product Name | Part Number |
Cisco 7600 ES+XC Combo 10x1GE/ 1x10GE, DFC3C | 76-ES+XC-20G3C |
Cisco 7600 ES+XC Combo 10x1GE/ 1x10GE, DFC3CXL | 76-ES+XC-20G3CXL |
Cisco 7600 ES+XC Combo 20x1GE/ 2x10GE, DFC3C | 76-ES+XC-40G3C |
Cisco 7600 ES+XC Combo 20x1GE/ 2x10GE, DFC3CXL | 76-ES+XC-40G3CXL |
Cisco 7600 Series Ethernet Services Plus Basic License | 76-ES+BASIC-LIC |
Cisco 7600 Series Ethernet Services Plus Advanced License | 76-ES+ADVIP-LIC |
Cisco 7600 Series ES+ OTN PHY (G.709/FEC/EFEC) License (Available in a future software release on 10G ports only) | 76-ES+OTN-LIC |
Cisco 7600 Series Ethernet Services Plus Intelligent Services Gateway License | 76-ES+ISG-LIC |
Cisco 7600 Series Ethernet Services Plus Video Monitoring License | 76-ES+VIDEO-LIC |